Novaris SLM offers protection for up to 12 signal lines. Each of the 12 lines have the protection referenced to ground making it an excellent choice for parallel signaling busses. Typical applications include process control, telemetry, PLC, and irrigation systems.
Use SD – MULTIMOV high energy surge diverters for single phase point of entry protection at main switchboards. Models are available for all wiring systems worldwide. SD MULTIMOV surge diverters feature a parallel redundant arrangement of high energy metal oxide varistors (MOVs), thus promoting long life and exceptional surge handling capacity. In the event of a varistor failure the remaining segments continue to provide protection. A digital display confirms the device rating by displaying the percentage active of the redundant segments. The display indicates segment status and thermal overload. A failsafe alarm contact allows for remote monitoring.
The electro-pneumatic dosing meter OKtronic combines the precise metering of approved oval wheel meter, the intelligent elektronic and modern valve technology to a robust and universal applicable metering unit. pdf datasheet
The Flowal Plus is a versatile flowmeter for measuring the volume of liquids in mechanical engineering, factory automation and process instrumentation combined with modern electronics. It is suited for industrial fluids, chemical fluids, mineral oils and fuels. , 0.03 -600 l/min, accuracy up to ±0,25% pdf datasheet
The Premium Oval Wheel Meter Type OaP for liquid raw, intermediate and finished hydrocarbon and chemical liquids: double case, custody transfer, SIL2 certified, 5 -24,000 l/min, accuracy up to ±0,05% pdf datasheet
This meter is designed for the measurement non-conductive liquids, e.g. oil or demineralized water. An inlet or outlet section is not required., 0.2 -100 l/min, accuracy up to ±0,25% pdf datasheet
Oval wheel meters type OI are used for the measurement of liquid products such as liquefied gases, acids, alkaline solutions, fats, alcohols, solvents, dispersions, polymers, poly-condensates, paints, colors and adhesives, 0.2 -1,200 l/min, accuracy up to ±0,1% download pdf datasheet
Oval wheel meters type OK are used for dosing of liquid chemical fluids such as solvents, resins, paints and varnishes, alkalis, organic and inorganic acids, depending on temperature and concentration., 0.2 -1,200 l/min, accuracy up to ±0,1% pdf datasheet
Oval wheel meters type OP are used for measuring liquids such as gasolines, heating/lubricating/diesel oil, bio ethanol, chemical liquids, 0.08-5,000 l/min, accuracy up to ±0,2% pdf datasheet
The Trigear PD Flowmeter outperforms its competitors when it comes to the accurate metering of the majority of clean fluids including fuels, oils, additives, chemicals, food bases, paints, viscous emulsions, insecticides, alcohols and solvents whether they be pumped or gravity fed. pdf datasheet
PDM machines are designed for the axial machining and facing of fitting housings (gate valves, valves, check valves), pumps and similar rotationally symmetrical components. They have infinitely variable speed control and axial and radial feeds (Z and X axis) with infinitely variable control that make it possible to move both axes simultaneously at different speeds. They are equipped with CNC programs that are specially tailored to turning requirements. During program development, special attention was paid to making operation as simple as possible. Operation takes place using a portable electronic control unit.
The Aplisens Electro-Magnetic Flometer PEM is suitable for bidirectional measurement of liquids: acids, alkalis, paints, waste, water/waste water download pdf datasheet
The PRP Pitot Tube Flowsensor measures the flow in pipes and ducts according to the differential pressure working principle. It allows bidirectional flow with low pressure loss, low maintenance and installation cost and accurate long term reading. download pdf datasheet
Stand-alone Deadweight Tester / Pressure Balance LR-Cal LDW-P, Pneumatic, max. 100 bar download pdf datasheet
The pressure test pump LR-Cal 2911 is used to generate pressure up to 7 bar for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements download pdf datasheet
Pressure Comparator, pneumatic hand lever pump - bench type. Pressure generation up to +60 bar, switchable to Vacuum generation up to -0.95 bar. Medium: ambient air. download pdf datasheet
Pressure Comparator, pneumatic hand lever pump. Pressure generation up to +100 bar, switchable to Vaccum generation up to -0.95 bar. Medium: ambient air. download pdf datasheet
Air operated pressure controller LCC100 (no external source required) for pressure up to 2000 mbar, DP, Vacuum down to -650 mbar download pdf datasheet
Manually pressure and vacuum generation (-0,85...+8 bar) for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements in the low-pressure and vacuum range. download pdf datasheet
Manually pressure generation up to 40 bar, switchable to manually vacuum generation up to -0.95 bar. Pneumatic, operated with ambient air download pdf datasheet
Manually pressure generation up to 60 bar, switchable to manually vacuum generation up to -0.95 bar Pneumatic, operated with ambient air download pdf datasheet
The vacuum test pump LR-Cal 2941 is used to generate vacuum (negative pressure down to -0.9 bar) for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. download pdf datasheet
Portable valve test bench for testing safety valves DN 10 (3/8“) - DN 80 (3“) pdf Testbench
The portable PS-T 10 is suitable for testing shut-off valves and safety valves. The test specimens are clamped vertically and can be optimally vented by filling from below. pdf Testbench
Precision Pressure Transmitter, adjustable ranges from 0...400 mbar to 0...600 bar, accuracy 0.1% FS, intrinsically safe Exia option pdf datasheet
Precision Pressure Transmitter DMP 334i, adjustable ranges from 0...600 bar to 0...2200 bar, accuracy 0.1% FS pdf datasheet
The reference thermometer LR-Cal LRT 750 is a comparison reference for checking The Precision Reference Thermometer Model LR-Cal LRT 1000 is a very high accurate reference for comparison temperature measurements. download pdf datasheet
The reference thermometer LR-Cal LRT 750 is a comparison reference for checking and calibrating all kind of thermometer. The system consists of a battery powered digital handheld indicator and a pre-aged precision sensor with temperature range -200...+450°C. download pdf datasheet
The electronic DS pressure switch with ceramic sensor, intrinsically safe for gases (Exia), Pressure ranges up to 600 bar pdf datasheet DS401 pdf datasheet DS201 pdf datasheet DS230
The electronic DS-P pressure switch Stainless steel diaphragm, flush, for hygienic, paint, chemical, high viscosity applications pdf datasheet DS200P pdf datasheet DS400P