The differential pressure transmitter PRE-28 from Europe is applicable to the measurement of differential pressure of gases, vapors and liquids. Range: 0...25 mbar upto 0-25 bar download pdf datasheet
The PCE-28 pressure transmitter is applicable to the measurement of the pressure, vaccum pressure and absolute pressure of gases, vapours and liquids. Range from 0...1 bar up to 0...1000 bar 4-20 mA output signal +HART protocol download pdf datasheet
The APLISENS APC-2000 ALW Smart Pressure Transmitter from Europe gives accurate measurement for Absolute, Gauge and Vaccum pressure of gases, vapors and liquids. Range: min -7 to 7 mbar, max 0 to 1000 bar download pdf datasheet
The PCE-28 pressure transmitter is applicable to the measurement of the pressure, vaccum pressure and absolute pressure of gases, vapours and liquids. Range from 0...25 mbar up to 0...1000 bar, (opt. Modbus RTU) download pdf datasheet
The APR-2000 ALW transmitter from Europe is applicable to the measurement of differential pressure of gases, vapours and liquids. Range: min -7 to 7 mbar, max 0-70 bar download pdf datasheet
Smart differential pressure transmitter PRE-28 SMART from Europe is applicable to the measurement of differential pressure. Range: -25...25 mbar, max 0-70 bar download pdf datasheet
Smart differential pressure transmitters with direct diaphragm seals pdf datasheet
The APR-2200 ALW transmitter with 2 diaphragm seals from Europe is applicable to the measurement of differential pressure of gases, vapours and liquids. pdf datasheet
MS 100 Industrial Pressure Gauges are applicable to the measurement of the pressure of liquids and gases at temperatures up to 200 degrees C. fully stainless steel, 100 mm diameter download pdf datasheet
MS 100 KS Industrial Pressure Gauges with Diaphragm Seals are applicable at temperatures from -60 up to 315 degrees C to measure the pressure of contaminated, viscous,solidifying chemically reactive media at high or low temperature in case of mechanical vibration or pulsation pressure. fully stainless steel, 100 mm diameter download pdf datasheet
The diaphragm seal is a pressure-transmitting, diaphragm-type device. The pressure signal is sent to the cooperating pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure measuring device from damaging impacts caused by either medium or installation: – low or high temperature, increased viscosity, impurities – vibrations of the installation (remote diaphragm seal) download pdf datasheet
Flanged Seals with extended diaphragms are used for multi walled tanks where the diaphragm will be placed close to the inner wall download pdf datasheet
S-TK-P Seals have an inbuild 2 channel cleaning system to clean the membrane without dismounting it. download pdf datasheet
Chemical Seals are used for pressure measurement of highly corrosive media. Different materials for wetted parts can be applied: Hastelloy, Nickel, Monel, Titanium, Tantalum, Teflon. download pdf datasheet
S-Comp Seals have a large separating diaphragm (70 mm diameter) to take measurement of a narrow range, they are easy to install. pdf datasheet
Chemical Seals are used for pressure measurement of corrosive media such as hydrochloric, sulfuric and nitric acids or chlorine. download pdf datasheet
Sanitary Seals isolate the pressure measuring device from damaging impacts caused by the medium or the installation to avoid impurities download pdf datasheet
S-Mazut Seals are applicable for the measurement of viscous liquids at temperatures of 150 degrees C (300 deg C with remote diaphragm seals) to measure the pressure of heavy fuel oil (petroleum atmospheric residue) in burners and heat centers of power boilers. download pdf datasheet
S-RC Seals are applicable for the measurement of hot, viscous, solidifying or contaminated liquids where an impulse line cannot be used download pdf datasheet
Hydrostatic Level Probes for Tank level measurement Range from 1 up to 500 m H2O download pdf datasheet
differential pressure transmitter for level measurement in pressure tanks based on 2 absolute pressure transmitters download pdf datasheet
The APRE-2200 ALW transmitter with 2 diaphragm seals from Europe is applicable to the measurement of differential pressure of gases, vapor and liquids for filter-loss and pressure tank applications download pdf datasheet
The Aplisens Smart Temperature Transmitter APT-2000 ALW from Europe is applicable to the measurement of temperature. The RTD PT100 sensing element ranges from -200°C to 550°C, (TC type K from -40°C to 550°C). The device is suitable for custody transfer measurement of gas. download pdf datasheet
The Smart Temperature Transmitter LI-24ALW is applicable to converting resistance of temperature or voltage of thermocouple sensor to standard current signal 4-20mA. The transmitter has two separate channels enabling measurement of temperature difference, average, average with redundancy, max. or min. temperature. download pdf datasheet
The Aplisens temperature transmitter LI-24G is applicable to converting resistance of temperature or voltage of thermocouple sensor to a standard current signal 4-20mA. The transmitter has two separate measuring channels enabling measurement of temperature difference, average, average with redundancy, max or min temperature. download pdf datasheet
The Aplisens Electro-Magnetic Flometer PEM is suitable for bidirectional measurement of liquids: acids, alkalis, paints, waste, water/waste water download pdf datasheet
The Aplisens Nozzle Flowmeter ZPK is suitable for flow measurement of liquids in closed pipelines download pdf datasheet
To measure heating fuel consumption by oil burners (for example, in heating boilers, industrial furnaces, tar processing plants), Mineral Oils, Consumption monitoring and optimization (ships, generators and large vehicles, etc.), Manual Dosing/Batching pdf datasheet
To measure heating fuel consumption by oil burners (for example, in heating boilers, industrial furnaces, tar processing plants), light and extra light mineral Oils, Consumption monitoring and optimization (ships, generators and large vehicles, etc.) pdf datasheet