Turbine Flowmeter RQ Bopp & Reuther

Oval Wheel Flowmeter OD

SKU: OD

Manufacturer: Bopp Reuther

This meter is designed for the measurement non-conductive liquids, e.g. oil or demineralized water. An inlet or outlet section is not required., 0.2 -100 l/min, accuracy up to ±0,25%

pdf datasheet

Special Features:

  • Fillings from 10 ml possible
  • very short dosing times > 250ms
  • high resolution (e.g. DN10: 2000 pulses/l)
  • large selection of filling quantities with different nominal sizes
  • can be combined with the batch controller

Characteristics:

  • direct measurement of volume
  • measurement of non-conductive and conductive liquids
  • high accuracy / repeatability also for small quantities
  • high long-term stability

Technical Data:

Nominal size DN10,DN15,DN25
Process connection TriClamp according to DIN 32676
Material

Housing: stainless steel

Oval wheels: stainless steel, PEEK

Seals: EPDM, alternatively Viton

Flow Range

0.2 to 5 l/min  –  2,000 Pulses/
(0.05 to 1.32 gal/min)l

1 to 30 l/min  –  1,000 Pulses/l
(0.26 to 7.93 gal/min)

2 to 50 l/min – 400 Pulses/l
(0.53 to 13.21 gal/min)

4 to 100 l/min – 200 Pulses/l
(1.06 to 24.42 gal/min)

Accuracy ±0,25% to ±0,5%
Repeatability ±0,1%
Viscosity 0,3 to 1.500 mPa·s
Process temperature

Liquid temperature: -10°C to +130°C (-14°F to 266°F)

ambient temperature: -20°C to +70°C (-4°F to 158°F)

Process pressure max. 16 bar
Ex-protection
not available