Manually pressure generation up to 40 bar, switchable to manually vacuum generation up to -0.95 bar. Pneumatic, operated with ambient air download pdf datasheet
Stand-alone Deadweight Tester / Pressure Balance LR-Cal LDW-P, Pneumatic, max. 100 bar download pdf datasheet
Differential Pressure, Stand-alone Deadweight Tester / Pressure Balance LR-Cal CBP5000-DP download pdf datasheet
High Pressure, Stand-alone Deadweight Tester / Pressure Balance LR-Cal CBP5000-HP, Hydraulic, max. 5000 bar download pdf datasheet
High Accuracy, Stand-alone Deadweight Tester / Pressure Balance LR-Cal LDW-H, Hydraulic, max. 1400 bar download pdf datasheet
Complete Stand-alone Deadweight Tester / Pressure Balance LR-Cal LDW-HK Deadweight Tester / Pressure Balance, LR-Cal LDW-HK Hydraulic, max. 1200 bar download pdf datasheet
Manually pressure and vacuum generation (-0,85...+8 bar) for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements in the low-pressure and vacuum range. download pdf datasheet
The pressure test pump LR-Cal 2911 is used to generate pressure up to 7 bar for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements download pdf datasheet
The vacuum test pump LR-Cal 2941 is used to generate vacuum (negative pressure down to -0.9 bar) for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. download pdf datasheet
The digital pressure gauges DM 80, DM 80-UMS, DM 80-S are used for inidcation of measured pressure values, for testing and diagnose purposes in hydraulic applications download pdf datasheet
Pressure Transmitter LPT533 with IO-Link interface, adjustable ranges from 0...100 mbar to 0...400 bar, accuracy 0.35% FS (opt 0.25%FS) pdf datasheet
Precision Pressure Transmitter, adjustable ranges from 0...400 mbar to 0...600 bar, accuracy 0.1% FS, intrinsically safe Exia option pdf datasheet
Precision Pressure Transmitter DMP 334i, adjustable ranges from 0...600 bar to 0...2200 bar, accuracy 0.1% FS pdf datasheet
The ultra-high-pressure transmitter type DMP 304 with rugged stainless steel housing for applications with highest demand on precision and reliability. DMP 304 series is based on a compensated strain gauge, bonded onto a stainless steel diaphragm - adjustable ranges from 0...2000 bar to 0...6000 bar, accuracy 0.5% FS (opt 0. 25%FS) pdf datasheet
The electronic pressure switch LDS 350-IO with an integrated IO-Link interface to exchange process data, diagnostic reports and status messages and control the process application. Pressure ranges from 0 ... 100 mbar up to 0 ... 600 bar pdf datasheet
The electronic universal DS pressure switch with stainless steel sensor, intrinsically safe for gases (Exia), Pressure ranges from 0...100 mbar to 0...600 bar pdf datasheet DS400 pdf datasheet DS200 pdf datasheet DS202
The electronic DS pressure switch with ceramic sensor, intrinsically safe for gases (Exia), Pressure ranges up to 600 bar pdf datasheet DS401 pdf datasheet DS201 pdf datasheet DS230
The electronic DS210 low and vacuum pressure switch. Pressure ranges 0...10 mbar to 0...1 bar and vacuum -1...0 bar pdf datasheet
The electronic DS214 high pressure switch with pressure ranges from 0...600 bar to 0...2200 bar pdf datasheet
The electronic DS-P pressure switch Stainless steel diaphragm, flush, for hygienic, paint, chemical, high viscosity applications pdf datasheet DS200P pdf datasheet DS400P
The DS4 electronic pressure switch for Silizium sensor for pneumatic applications. Pressure ranges 0...10 mbar to 0...1 bar and vacuum -1...0 bar pdf datasheet
The mechanical diaphragm pressure switch with ranges from 0...1 bar to 0...25 bar and vacuum pdf datasheet
The mechanical diaphragm pressure switch with for vacuum and compound pressure upto 160 bar pdf datasheet 03.40 pdf datasheet 03.27
The mechanical Bourdon Tube pressure switch for rough working conditions with aggressive fluids or high temperature. Range: vacuum and compound pressure up to 600 bar pdf datasheet
The electronic temperature switch LTS 300-IO with an IO-Link interface as standard in order to exchange process data, system monitoring, diagnostic reports and status messages with a superordinate control level, from -40°C to 150°C pdf datasheet
High accurate handheld for Barometric Air Pressure, Range: 800...1100 mbar absolute, Touch-Screen, battery operated, data logging, PC software "SmartGraph3" download pdf datasheet
The industrial pressure transmitter LPT 336 with a welded stainless steel sensor for hydrogen, oxygen and other technical gas applications pdf datasheet
The Premium Oval Wheel Meter Type OaP for liquid raw, intermediate and finished hydrocarbon and chemical liquids: double case, custody transfer, SIL2 certified, 5 -24,000 l/min, accuracy up to ±0,05% pdf datasheet
Oval wheel meters type OP are used for measuring liquids such as gasolines, heating/lubricating/diesel oil, bio ethanol, chemical liquids, 0.08-5,000 l/min, accuracy up to ±0,2% pdf datasheet
Oval wheel meters type OI are used for the measurement of liquid products such as liquefied gases, acids, alkaline solutions, fats, alcohols, solvents, dispersions, polymers, poly-condensates, paints, colors and adhesives, 0.2 -1,200 l/min, accuracy up to ±0,1% pdf datasheet
Oval wheel meters type OK are used for dosing of liquid chemical fluids such as solvents, resins, paints and varnishes, alkalis, organic and inorganic acids, depending on temperature and concentration., 0.2 -1,200 l/min, accuracy up to ±0,1% pdf datasheet
The Flowal Plus is a versatile flowmeter for measuring the volume of liquids in mechanical engineering, factory automation and process instrumentation combined with modern electronics. It is suited for industrial fluids, chemical fluids, mineral oils and fuels. , 0.03 -600 l/min, accuracy up to ±0,25% pdf datasheet
This meter is designed for the measurement non-conductive liquids, e.g. oil or demineralized water. An inlet or outlet section is not required., 0.2 -100 l/min, accuracy up to ±0,25% pdf datasheet
The Turbine Flowmeter RQ Measuring liquids and liquefied gases in the chemical and petrochemical industry, in the mineral oil industry and loading systems, especially for high operating pressures and low viscosities, 0.15 to 2,400 m³/h, accuracy up to ±0,15% pdf datasheet
The compact orifice Oriflow for flow measurements of conductive and non-conductive fluids, gases and vapours, volume/mass measurement pdf datasheet
General purpose magnetic inductive flowmeter for applications in the water / waste water industry pdf datasheet
The flow computers are used to record, display and output mass and volume flows, including the calculation of net values for standard conditions. pdf datasheet
Strainers are used to avoid measuring errors and damage caused by solid particles contained in the fluid. pdf datasheet
Centrifugal Air Separators are used to avoid measuring errors that result from air or gas contained in liquids measured with volumetric and mass flow meters. pdf datasheet
Metering Skid Solutions for Batch Measurement: Loading / Unloading, Continuous Measurement: Pipeline Blending and Additive Injection Units Dosing pdf datasheet
The electro-pneumatic dosing meter OKtronic combines the precise metering of approved oval wheel meter, the intelligent elektronic and modern valve technology to a robust and universal applicable metering unit. pdf datasheet
Dosing and Filling Stations for oil and water based media - Palm Oil, Oils & Fuels and waterbased beverages, pharmaceutical and chemical liquids pdf datasheet
The liquid density meter of the DIMF series is used for continuous measurement of the density/concentration of liquids or liquid mixtures. The proven tuning fork principle guarantees a high acccuracy with very good long term stability.The robust design ensures reliable operation even under harsh operating conditions. pdf datasheet